Simultaneous fluoride and arsenic removal from groundwater by using aluminium sacrificial anode

Ihos Monica and Manea Florica and Pode Rodica: Simultaneous fluoride and arsenic removal from groundwater by using aluminium sacrificial anode.

[thumbnail of proceedings_of_isaep_2016_176-179.pdf]
Preview
Cikk, tanulmány, mű
proceedings_of_isaep_2016_176-179.pdf

Download (533kB) | Preview

Abstract

The simultaneous removal of fluoride and arsenic in groundwater collected from three deep wells situated in Western part of Romania was carried out by electrocoagulation (EC) with aluminium sacrificial anode. The current density was of 156, 480 and 780 A/m2 , respectively and the electrolysis time 60 min. The removal efficiency of fluoride and arsenic was determined based on their residual concentration. Also, the specific energy consumption was calculated and it was in the range of 0.14 - 1.40 kWh/m3.

Item Type: Conference or Workshop Item
Journal or Publication Title: Proceedings of the International Symposium on Analytical and Environmental Problems
Date: 2016
Volume: 22
ISBN: 978-963-306-507-5
Page Range: pp. 176-179
Event Title: International Symposium on Analytical and Environmental Problems (22.) (2016) (Szeged)
Related URLs: http://acta.bibl.u-szeged.hu/55893/
Uncontrolled Keywords: Talajvíz - szennyeződés - mérés
Additional Information: Bibliogr.: 179. p. ; összefoglalás angol nyelven
Date Deposited: 2018. Dec. 11. 16:44
Last Modified: 2022. Aug. 08. 15:48
URI: http://acta.bibl.u-szeged.hu/id/eprint/56069

Actions (login required)