Humic acid removal from surface water using ultrafiltration membrane

Simonič, Marjana: Humic acid removal from surface water using ultrafiltration membrane. Proceedings of the International Symposium on Analytical and Environmental Problems, (24). pp. 207-210. (2018)

[img] Cikk, tanulmány, mű
proceedings_of_isaep_2018_207-210.pdf

Download (984kB)

Abstract

The main focus of research was to purify surface water with ultrafiltration, so it could be used as a source of drinking water. By measuring individual parameters and performing physical and chemical analysis, we determined the influence of natural organic matter (NOM) and checked the membrane fouling. The operation of the membrane was carried out at various transmembrane pressures (TMp) (2, 3 and 4 bar). Purification with UF was carried out on the Memcell device with regenerated cellulose membrane type NADIR® PM UC030 with NMWCO of 30 kDa. With increasing pressure, the quality of the purified water increased. At 4 bars, the COD was totally removed from the Mura river sample.

Item Type: Article
Journal or Publication Title: Proceedings of the International Symposium on Analytical and Environmental Problems
Date: 2018
Volume: 24
Page Range: pp. 207-210
ISBN: 978-963-306-623-2
Uncontrolled Keywords: Membránszűrés, Kémia
Additional Information: Bibliogr.: 210. p. ; ill. ; összefoglalás angol nyelven
Date Deposited: 2019. Jan. 07. 09:15
Last Modified: 2019. Jan. 07. 09:15
URI: http://acta.bibl.u-szeged.hu/id/eprint/56324

Actions (login required)

View Item View Item